top of page

What to do if your alcohol sprayer doesn't work? 7 ways to solve common problems, professional technician edition (no need to rely on a technician)

เครื่องพ่นแอลกอฮอล์อัตโนมัติ รุ่น HAS-003/S-W หน้าทางเข้าอาคาร
เครื่องพ่นแอลกอฮอล์อัตโนมัติ รุ่น HAS-003/S-W หน้าทางเข้าอาคาร

Have you ever bought an alcohol sprayer and installed it for a short while, and it suddenly started acting up? Sometimes the liquid doesn't come out, the sensor doesn't work, or even after adding liquid, the machine is completely silent. These problems are a headache for purchasing departments and housekeepers in many organizations.

But wait! Don't throw away your device or call a technician right away, as 80% of alcohol sprayer problems can be fixed within 5 minutes.

In this article, Hygienic will reveal a "repairman's" guide that lists 7 common symptoms along with easy solutions to help you save on repair costs and maximize the lifespan of your machine.


⚡ Summary table: How to troubleshoot alcohol sprayers

Common symptoms

Primary cause

Immediate solutions

1. The liquid does not spray/little amount comes out.

Clogged head, viscous liquid, weak carbon

Use warm water to clean the spray head and replace the entire set of batteries.

2. The sensor does not work.

Glare, dust

Move the spot away from sunlight, wipe the sensor surface.

3. Changed the battery and it still won't turn on.

Rusty battery terminals, incorrect battery insertion

Clean the rust on the terminals, check the +/- polarity to be correct.

4. Leakage of fluid

The lid is not tight, the O-ring is worn out.

Tighten the cap, replace the O-ring.

5. The machine sprays itself continuously.

Dirty sensor, faulty battery

Clean the sensor, reset the device.

Deep dive into 7 problems and how to repair alcohol sprayers yourself.


1. Problem: The liquid does not spray or sprays out in a very light mist.


This is the number one problem reported by customers. The main cause is usually not the machine itself, but rather "what's added."

  • cause:

    • Using a liquid with too high a viscosity (e.g. accidentally adding gel to a spray nozzle model)

    • The spray head is clogged with dried sediment.

    • The battery is almost dead, causing the motor to have no voltage.

  • ✔ Solution:

    • Never use gel. If the machine specifies a spray head, use only clear alcohol.

    • Cleaning the nozzle: Remove the nozzle and soak it in "warm water" for about 10 minutes to dissolve the sediment.

    • Battery Replacement: It is recommended to use only alkaline batteries for stable power.


2. Problem: Put your hand under it and it's quiet (sensor doesn't detect movement)


Many people think that the sensor is broken, but in fact it could be due to "light" or "cleanliness".

  • cause:

    • Install in a location where there is direct sunlight or a spotlight that is too bright (infrared light from the sun interferes with the signal).

    • There is a thick layer of liquid or dust on the sensor glass window.

  • ✔ Solution:

    • Move the installation location away from strong sunlight.

    • Use a soft, damp cloth to wipe clean the "sensor eye" area under the device.


3. Problem: I have replaced the battery but the device still doesn't work.


  • cause:

    • Rust eats the terminal: Moisture from the evaporated alcohol eats the carbon spring terminal, causing green/white rust, causing the electricity to not flow.

    • Use mixed brand of charcoal or mix old charcoal with new charcoal.

  • ✔ Solution:

    • Use sandpaper to lightly polish or a multi-purpose cleaner to wipe off the rust from the battery terminals.

    • Golden rule: Always replace the batteries with a new set of batteries, and always use the same brand.


4. Problem: The liquid leaks or drips onto the floor.


This problem creates a mess and is dangerous to the surface.

  • cause:

    • The tank cap is not closed tightly, causing an incomplete vacuum.

    • The O-ring is deteriorated or torn.

  • ✔ Solution:

    • Check the threads of the refrigerant tank cap.

    • If the O-ring is broken, we recommend contacting the service center to purchase replacement parts (Hygienic customers can inform the admin).


5. Problem: The liquid ran out without my knowing (no notification)


Budget-friendly models often lack warning lights, which can frustrate users when the fluid runs out.

  • ✔ Solution:

    • Set a schedule to check the liquid level every 2-3 days.

    • A better choice: Choose a model with a large "Transparent Window" such as the [Hygienic HAS-003/SW] model, which allows you to clearly see the fluid level from a distance without having to open the lid.


6. Problem: The machine breaks down abnormally quickly (motor burns out/gear breaks)


Often occurs in factories or schools that have heavy use (Heavy Duty) but choose to use a machine with "Home Use" specifications.

  • ✔ Solution:

    • Choose the right machine for the job: If it is used more than 100 times/day, choose a Heavy Duty model with a durable motor, such as the [HAS-006/S, HAS-006/D or HAS-003/S, HAS-003/D] model for factories.

    • Rest the device: If there is continuous use (such as during work), it is recommended to take a small break.


7. Problem: Employees just walk by and refuse to use the machine.


No matter how good a device is, if no one uses it, it is worthless. The problem lies in the "UX" (user experience).

  • ✔ Solution:

    • Prominent location: Install at eye level or near the door handle.

    • The machine must be fast: If the sprayer is slow (delay more than 1 second), people will not wait. It is recommended to adjust the amount of liquid dispensed to be appropriate (0.8– 1 ml) for speed.


🏆 Why do leading organizations choose alcohol sprayers from Hygienic?


Troubleshooting on the job is great, but wouldn't it be better if you could use a "durable" machine with "after-sales service" support?

With experience serving corporate clients like KFC, Milott Laboratories, NMB Minebea and leading schools, what makes Hygienic different is:

  1. Industrial grade spare parts: A+ grade sensors and nozzles reduce clogging problems.

  2. On-Site Service: We dare to guarantee and have a team of technicians to visit the work site (according to contract conditions). No need to remove the machine and send it for repair yourself.

  3. Complete spare parts: Whether it's the liquid tank, cap or spray head, we have genuine spare parts in stock for the entire life of the product.


summarize

This is a revised version of this article, written primarily with a focus on SEO and Google AI Overviews .

I've restructured the page to include a summary table , bolding, and FAQ to make it easier for Google bots to understand, and seamlessly incorporated Hygienic's selling points.


Article topic: Alcohol sprayer not working, what to do? 7 ways to solve common problems, professional technician edition (no need to call a technician)


(Suggested URL slug: /blog/fix-automatic-alcohol-dispenser-problems)

[Introduction]

Have you ever bought an alcohol sprayer and installed it for a short while, and it suddenly started acting up? Sometimes the liquid doesn't come out, the sensor doesn't work, or even after adding liquid, the machine is completely silent. These problems are a headache for purchasing departments and housekeepers in many organizations.

But wait! Don't throw away your device or call a technician right away, as 80% of alcohol sprayer problems can be fixed within 5 minutes.

In this article, Hygienic will reveal a "repairman's" guide that lists 7 common symptoms along with easy solutions to help you save on repair costs and maximize the lifespan of your machine.


⚡ Summary table: How to troubleshoot alcohol sprayers (urgent edition)


(Google AI loves this data.)

Common symptoms

Primary cause

Immediate solutions

1. The liquid does not spray/little amount comes out.

Clogged head, viscous liquid, weak carbon

Use warm water to clean the spray head and replace the entire set of batteries.

2. The sensor does not work.

Glare, dust

Move the spot away from sunlight, wipe the sensor surface.

3. Changed the battery and it still won't turn on.

Rusty battery terminals, incorrect battery insertion

Clean the rust on the terminals, check the +/- polarity to be correct.

4. Leakage of fluid

The lid is not tight, the O-ring is worn out.

Tighten the cap, replace the O-ring.

5. The machine sprays itself continuously.

Dirty sensor, faulty battery

Clean the sensor, reset the device.


Deep dive into 7 problems and how to repair alcohol sprayers yourself.



1. Problem: The liquid does not spray or sprays out in a very light mist.


This is the number one problem reported by customers. The main cause is usually not the machine itself, but rather "what's added."

  • cause:

    • Using a liquid with too high a viscosity (e.g. accidentally adding gel to a spray nozzle model)

    • The spray head is clogged with dried sediment.

    • The battery is almost dead, causing the motor to have no voltage.

  • ✔ Solution:

    • Never use gel. If the machine specifies a spray head, use only clear alcohol.

    • Cleaning the nozzle: Remove the nozzle and soak it in "warm water" for about 10 minutes to dissolve the sediment.

    • Battery Replacement: It is recommended to use only alkaline batteries for stable power.


ตัวอย่าง หัวจ่าย แบบ สเปรย์และแบบหยด
ตัวอย่าง หัวจ่าย แบบ สเปรย์และแบบหยด

2. Problem: Put your hand under it and it's quiet (sensor doesn't detect movement)


Many people think that the sensor is broken, but in fact it could be due to "light" or "cleanliness".

  • cause:

    • Install in a location where there is direct sunlight or a spotlight that is too bright (infrared light from the sun interferes with the signal).

    • There is a thick layer of liquid or dust on the sensor glass window.

  • ✔ Solution:

    • Move the installation location away from strong sunlight.

    • Use a soft, damp cloth to wipe clean the "sensor eye" area under the device.


3. Problem: I have replaced the battery but the device still doesn't work.


  • cause:

    • Rust eats the terminal: Moisture from the evaporated alcohol eats the carbon spring terminal, causing green/white rust, causing the electricity to not flow.

    • Use mixed brand of charcoal or mix old charcoal with new charcoal.

  • ✔ Solution:

    • Use sandpaper to lightly polish or a multi-purpose cleaner to wipe off the rust from the battery terminals.

    • Golden rule: Always replace the batteries with a new set of batteries, and always use the same brand.

ree

4. Problem: The liquid leaks or drips onto the floor.


This problem creates a mess and is dangerous to the surface.

  • cause:

    • The tank cap is not closed tightly, causing an incomplete vacuum.

    • The O-ring is deteriorated or torn.

  • ✔ Solution:

    • Check the threads of the refrigerant tank cap.

    • If the O-ring is broken, we recommend contacting the service center to purchase replacement parts (Hygienic customers can inform the admin).


5. Problem: The liquid ran out without my knowing (no notification)


Budget-friendly models often lack warning lights, which can frustrate users when the fluid runs out.

  • ✔ Solution:

    • Set a schedule to check the liquid level every 2-3 days.

    • A better choice: Choose a model with a large "Transparent Window" such as the [Hygienic HAS-003/SW] model, which allows you to clearly see the fluid level from a distance without having to open the lid.


6. Problem: The machine breaks down abnormally quickly (motor burns out/gear breaks)


Often occurs in factories or schools that have heavy use (Heavy Duty) but choose to use a machine with "Home Use" specifications.

  • ✔ Solution:

    • Choose the right machine for the job: If it is used more than 100 times per day, choose a Heavy Duty model with a durable motor, such as the [HAS-006/D for factories] model.

    • Rest the device: If there is continuous use (such as during work), you should take a small break.


7. Problem: Employees just walk by and refuse to use the machine.


No matter how good a device is, if no one uses it, it is worthless. The problem lies in the "UX" (user experience).

  • ✔ Solution:

    • Prominent location: Install at eye level or near the door handle.

    • The machine must be fast: If the sprayer is slow (delay of more than 1 second), people will not wait. It is recommended to adjust the amount of liquid dispensed to be appropriate (0.6–0.8 ml) for speed.


🏆 Why do leading organizations choose alcohol sprayers from Hygienic?


Troubleshooting on the job is great, but wouldn't it be better if you could use a "durable" machine with "after-sales service" support?

With experience serving corporate clients like KFC, Shake Shack, NMB Minebea and leading schools, what makes Hygienic different is:

  1. Industrial grade spare parts: A+ grade sensors and nozzles reduce clogging problems.

  2. On-Site Service: We dare to guarantee and have a team of technicians to visit the work site (according to contract conditions). No need to remove the machine and send it for repair yourself.

  3. Complete spare parts: Whether it's the liquid tank, cap or spray head, we have genuine spare parts in stock for the entire life of the product.


summarize

Most problems with alcohol sprayers are caused by minor maintenance. If you follow these 7 tips, you're guaranteed to have your machine with you for 1-3 years.

But if you've tried fixing it and it still doesn't work, or you're looking for a new device that will "solve the problem" in the long run?

Consult with the experts at Hygienic. We are ready to recommend the most suitable model for your job.

📲 LINE: @hygienic

📞 Call: 02-743-3940



 
 
 

Comments


Contact

Hygienic Corporation Co.,Ltd.  
1/26 Soi Supaphong 3 Yak 8, Nongbon, Pravet, Bangkok 10250 

Mobile :  087-5001616 Tel :  02-7433940-1   Fax :  02-7433942
Line ID :  @hygieniccorp  

e-mail :  admin@hygienic.co.th  

  • Black Facebook Icon
  • Black Instagram Icon
  • Black YouTube Icon
  • TikTok
  • Line

© 2035 by Gamma. Powered and secured by Wix

bottom of page